OMRON HEM-637 MANUAL DOWNLOAD

adminComment(0)

Instruction Manual. Wrist Blood Pressure Monitor with Advanced Positioning. Sensor (APS). Model HEM HEM REV A 1/26/ Omron healthcare instruction manual wrist blood pressure monitor with advanced positioning sensor (aps) hem Page 1 Instruction Manual Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS) Model HEM Thank you for downloading the Omron Wrist Blood Pressure. Manuals and User Guides for Omron HEM We have 1 Omron HEM manual available for free PDF download: Instruction Manual. Omron Healthcare Instruction Manual Wrist Blood Pressure Monitor with Advanced Positioning Sensor (APS) HEM


Omron Hem-637 Manual Download

Author:SHAROLYN HANAWALT
Language:English, Indonesian, Japanese
Country:Spain
Genre:Fiction & Literature
Pages:551
Published (Last):18.09.2016
ISBN:384-2-33275-283-4
ePub File Size:27.34 MB
PDF File Size:14.72 MB
Distribution:Free* [*Registration needed]
Downloads:27052
Uploaded by: MIGUELINA

Omron HEM Instruction Manual. Omron healthcare. I would say that the Omron HEM Wrist Blood Pressure Monitor with Advanced Positioning Sensor. Instruction manual • Read online or download PDF • Omron Healthcare HEM User Manual. We have published revised versions of the OMRON Privacy Policy and Cookie Policy. You can use the unique product code to find the Instruction Manual (IM), Declaration of Conformity It starts with HBF, HEM, HJ(A), HN, HV, MC or NE.

The device could be activated or inactivated without knowledge of the patients.

All patients were able to read and comprehend English and were given a written information sheet describing proper usage of the wrist monitor, which included diagrams. The measurements were performed at least 30 min after eating, smoking, or exercising and after 5 min of sitting in a chair equipped with an armrest and back support.

Auscultation was performed by two simultaneous observers using a single mercury manometer and dual-head stethoscope.

Omron Healthcare HEM-637 User Manual

The same two observers measured all of the auscultatory readings. Both observers were experienced in the auscultatory technique, although they were not specifically trained for this study. Each observer recorded their measurement on a separate paper without knowledge of the other measurement. The date of the measurement was also noted. Both the wrist manometer and the upper arm mercury measurements were attached to a data recorder on a laptop computer.

Omron Intellisense

All initial measurements were by the auscultatory technique. The second measurement was always by the Omron HEM wrist monitor.

The measurements were alternated in this sequence with a minimum of 1 min between readings. Observer comparison was made after the recorded fifth auscultatory value for determination of the total number of auscultatory measurements.

If the auscultatory SBP or DBP difference between observers was within 10 mm Hg, five auscultatory and four wrist measurements for each subject were recorded. If the auscultatory SBP or DBP difference was 10 mm Hg or more, an additional double auscultatory measurement was performed and recorded six total auscultatory readings.

Blood pressure self-measurement home BP The patients measured their blood pressure themselves with the oscillometric wrist instrument from Omron wrist instrument HEM- IT with position sensor. Between study days 1 and 7 and study days 8 and 14, the participants took two measurements on the left wrist each day in the morning between 6 and 9 a.

The antihypertensive treatment regime was not changed during the study period. Patients were instructed how to correctly use the oscillometric Omron wrist device for home BP measurement with a standardized 30 min. The blood pressure parameters of the first week day 1 to day 7 were compared with the results of the second week day 8 to day The home BP was measured in accordance with the user procedures and recommendations of the European Society of Hypertension [ 8 ]. In the period between 6 a.

Statistics The parameters investigated were anthroprometric data such as age, gender, height, body weight, body mass index, circumference of the wrist and of the upper arm.

The parameters of office BP were systolic and diastolic blood pressure and pulse pressure. The parameters of home BP were systolic and diastolic blood pressure, heart rate as well as pulse pressure.

The parameters of the ambulatory h ABPM were systolic and diastolic blood pressure, heart rate, and pulse pressure measured, for the total ambulatory 24 hour period, for the daytime 6 a. Before the evaluation, the systolic and diastolic blood pressure values were averaged for each method of measurement measurement in the doctor's office, h measurement and self-measurement over the respective visit to the doctor's office, day of measurement or the respective week of measurement.

Consequently, two values mean values were available for each of the methods. These had been measured at an interval of about one week.

The mean values determined in this way were the basis for the descriptive evaluation of the values measured with the different methods. In order to be able to compare the reproducibility of the three measurement strategies, the standard deviation of mean differences were compared.

You might also like: AISC STEEL MANUAL PDF

Student's t-test was used to statistically compare the SD of mean difference between measurement methods. Battery life is shorter under cold conditions such as during the winter.

Page 9: Automatic Memory Setting The monitor stores the measured values and the date and time of measurement, which is helpful for the continuous blood pressure management.

However, if more than one person is expected to use this monitor, the measured values of more than one person will be stored.

OMRON Healthcare Support

Push the SET button while the power is turned off. Page Wrist Selection Setting Measurement can be made on the left wrist or on the right wrist.

Keep pressing the button until the Measurement Screen is displayed. Select Left Wrist or Right Wrist. Page Alarm Setting Alarm Setting You can set the alarm to go off twice a day at a specified time in the morning and evening. In the same manner, set the hour for the second time and to go off.

Lock the setting.What is IntelliSense? The wrist sensor did improve the accuracy of the measurements compared to the subjects that had the sensor deactivated. In the Selection Screen, push either button for selection.

Omron Healthcare HEM-637 Blood Pressure Monitor User Manual

Moreover, there have been as yet not been any studies investigating the correlation of wrist measurements with end organ damage such as left ventricular hypertrophy.

Results Measurements not Included in the analysis Eighty subjects had both auscultatory and wrist measurements 47 in the Soff, 33 in the Son. By keeping track of your home blood pressure readings, you can provide your healthcare professional with a log of your measurements over time. Select Left Wrist or Right Wrist. Open Peer Review reports Background The reproducibility of office blood pressure office BP measurement in clinical studies as well as in doctor's offices is very limited for various reasons.